HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Replacing BA370, M2100 & M2200 Enclosure Elements
137HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
Installing cache modules in single-controller configurations
Perform the following steps to install HSG60 and HSG80 cache modules in
single-controller configurations.
Note: The replacement cache modules
must
contain the same memory configuration
as that of the cache module which was removed.
1. Insert each DIMM (from the cache module that was removed) straight into the
appropriate slot of the replacement cache module (see Figure 58 on
page 136). Ensure that the notches in the DIMM align with the tabs in the slot.
Use the following substeps to install the DIMMs:
a. Press the DIMM gently into the slot until it is seated at both ends.
b. Ensure that the two retaining clips for the DIMM are engaged.
c. Ensure that both ends of the DIMM are firmly seated in the slot and both
retaining clips engage the DIMM.
d. Repeat substep 1a through substep 1c above for each DIMM.
Caution: Misaligning the module can damage the backplane.
2. Carefully align and partially insert the cache module in the Cache A guide
rails.
Caution: If your cache module is in a BA370 enclosure, you must disable the
ECB. Failure to disable the ECB can result in cache module damage. To
disable the ECB, complete the following steps:
1. Disable the ECB by pressing the battery disable switch on the battery
module.
2. Connect the ECB Y-cable to the cache module.
3. Insert the replacement cache module completely into the appropriate bay, and
then engage the cache module retaining levers.
4. Connect a PC or terminal to the controller maintenance port for the
replacement cache module, if not already connected.