HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Replacing BA370, M2100 & M2200 Enclosure Elements
148 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
c. Verify the failover configuration by entering the following
commands:
SHOW THIS_CONTROLLER
SHOW OTHER_CONTROLLER
d. Verify that the controller cache and, if enabled, mirrored cache are
good. If either the cache or mirrored cache is not good, see Table 14
through Table 16 in the “Controller and Cache Replacement
Troubleshooting” appendix that starts on page 253 for more
information on clearing invalid or failed cache conditions.
e. Disconnect the PC or terminal from the controller maintenance port.