HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Replacing BA370, M2100 & M2200 Enclosure Elements
158 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
Replacing a PVA module
Use the following steps to replace a PVA module in a master enclosure or
expansion enclosure. The master enclosure contains array controllers and cache
modules; expansion enclosures do not.
Note: Array controllers can support up to three BA370 enclosures: a master enclosure
and two expansion enclosures.
A PVA can be replaced in either a single-controller or a dual-redundant controller
configuration using this procedure.
1. Connect a PC or terminal to the maintenance port of the operational
controller.
The controller connected to the PC or terminal becomes “this controller,” and
the second controller becomes the “other controller.”
2. In a dual-redundant controller configuration, disable Failover and take the
array controllers out of dual-redundant configuration with one of the
following commands:
SET NOFAILOVER
or
SET NOMULTIBUS_FAILOVER
3. Start FRUTIL with the following command:
RUN FRUTIL
4. Enter N(o) to the question about replacing the cache battery.
5. Enter 3 for the replace the PVA option.
Note: The
FRUTIL
PVA replacement menu provides options for three enclosures
regardless of how many enclosures are actually connected.
6. Select one of the following options:
Enter 1 to replace the PVA in a master enclosure.
Enter 2 to replace the PVA in the first expansion enclosure.
Enter 3 to replace the PVA in the second expansion enclosure.