HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Upgrading the Subsystem
215HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
An example of the subsequent screen (for the bottom controller) is displayed in
Figure 95. As you review Figure 95, note that units D11, D12, and D13 of
RAIDset R1 are partitioned RAIDsets. Also, RAIDset R5 has no units configured
above it.
Figure 95: Example of the screen displayed after issuing the SHOW RAIDSETS
SPECIAL_FUNCTION_ONE command (bottom controller)
The status of a RAIDset storage container is only valid on the controller owning
the RAID container. While taking action, work from the controller on which the
RAID container is owned.
Note: After invoking the REINITIALIZE container-name
SPECIAL_FUNCTION_ONE=PARTITION or REINITIALIZE
container-name SPECIAL_FUNCTION_ONE=NOPARTITION
command
in a dual-redundant controller configuration, ownership of the RAID container is
automatically transferred to the controller on which the command was
not
executed.
Repairing disk devices (offline and alternative methods)
This section covers the following topics:
Handling RAIDset containers with at least one unit above the container
(recommended offline method), page 216
Manually manipulating disk devices needing repair (alternative procedure),
page 216
Name Status Used by
R1 GOOD D11
D12
D13
R2 REPORTED ON OTHER CONTROLLER D2
R3 GOOD D3
R4 REPORTED ON OTHER CONTROLLER D4
R5 MAINTENANCE RECOMMENDED
R6 REPORTED ON OTHER CONTROLLER
R21 GOOD D21
R31 GOOD D31