HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Upgrading the Subsystem
217HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
Note: If only one or two RAIDsets are impacted and only a single device within each
RAIDset needs maintenance, you can use this alternative procedure.
1. Identify the RAIDset unit needing maintenance by issuing the following CLI
command:
HSG> SHOW RAIDSET SPECIAL_FUNCTION_ONE
Figure 96 and Figure 97 (on page 218) show an example of an affected
RAIDset.
Figure 96: Example of a RAIDset needing repair on the top controller (following
rolling upgrade v87P-6 to V88-1P)
HSG_TOP> SHOW RAIDSET SPECIAL_FUNCTION_ONE
Name Status Used by
-------------------------------------------------------------
R1 MAINTENANCE RECOMMENDED D7
R4 GOOD D10
R5 REPORTED ON OTHER CONTROLLER D8
RAID1 REPORTED ON OTHER CONTROLLER CO_RAID
RAID2 REPORTED ON OTHER CONTROLLER CO_RAID