HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Upgrading the Subsystem
222 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
9. Verify that the procedure was successful by ensuring that the affected
RAIDset is GOOD and placed in the appropriate RAIDset (see Figure 100 and
Figure 101).
Figure 100: Example of resulting RAIDset attributes
Figure 101: Example of the original RAIDset with a Good status
HSG_TOP> SHOW R1
Name Storageset Uses Used by
----------------------------------------------------------------------
R1 raidset DISK10200 D7
DISK20200
DISK30200
Switches:
NOPOLICY (for replacement)
RECONSTRUCT (priority) = NORMAL
CHUNKSIZE = 256 blocks
State:
RECONSTRUCT 2% complete on member DISK20200
DISK20200 (member 0) is RECONSTRUCTING 2% complete <<==
Reconstructing progress
DISK10200 (member 1) is NORMAL
DISK30200 (member 2) is NORMAL
HSG_TOP> SHOW RAIDSET SPECIAL_FUNCTION_ONE
Name Status Used by
----------------------------------------------------------------------------
R1 GOOD D7
R4 GOOD D10
R5 REPORTED ON OTHER CONTROLLER D8
RAID1 REPORTED ON OTHER CONTROLLER CO_RAID
RAID2 REPORTED ON OTHER CONTROLLER CO_RAID