HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Upgrading the Subsystem
244 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
9. Make sure that the program card is in the new controller, and then insert the
controller into its bay. Engage its retaining levers.
After fully seated, the newly installed controller automatically restarts. Press
Enter or Return to continue.
If the “other controller” did not restart, follow these steps:
a. Press and hold the “other controllerReset button.
b. Reseat the “other controller” program card.
c. Release the Reset button.
10. Connect all host bus cables to the new controller.
Note: If the controller being installed was previously used in another subsystem, it
must be purged of the old configuration (refer to the CONFIG RESET CLI command in
the
HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller
Software Command Line Interface Reference Guide
).
11. Enable failover, and establish the dual-redundant controller configuration
with the following command:
SET FAILOVER COPY=THIS_CONTROLLER
This command copies the subsystem configuration from “this controller” to
the new controller.
12. See the
HP StorageWorks HSG60 and HSG80 Array Controller and Array
Controller Software Command Line Reference Guide
to configure the controller.
13. Disconnect the PC or terminal from the controller maintenance port.