General Description
34 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
Cache module
Figure 6 and Table 7 identify the cache module and the location of the dual inline
memory module (DIMM). The bezel of the upgraded cache module is labeled
HSx80 CACHE.
Caution: An older version of the HP StorageWorks cache module (part
number 70-33256-01) cannot be used in Model 2100 and 2200 enclosures.
These enclosures require the updated version (part number 70-33256-11,
spare part number 70-33256-S1) to function properly. Failure to use the
updated version causes the array controller to become dysfunctional upon
starting.
Figure 6: Cache module
5017
1
2
Table 7: Cache module
Item Description
6–3
Part Number
2–5–2
Part Number
1 DIMM, 32 MB
DIMM, 128 MB
400296–001
400297–001
70–DIMS1–01
70–DIMS1–02
2 BA370 enclosure only:
- ECB Y-cable
1
, 1 meter
- ECB Y-cable, 3 meters
400298–001
401913–001
17–04479–03
17–04479–04
1. Cabling is not applicable to HSG60 subsystems