HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Common Replacement Information and Procedures
64 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
4. Install the access door on top of the controller and secure the door with the
screw.
5. Connect a PC or terminal to the maintenance port of the operational
controller.
Note: The controller connected to the PC or terminal becomes “this controller,” and
the controller being installed becomes theother controller.
6. Ensure that the controller configuration is customized to your needs, and then
record the controller configurations (for example, Failover mode, cache
status, serial numbers, SCSI mode, mirrored or nonmirrored information, and
so forth).
7. Start FRUTIL with the following command:
RUN FRUTIL
8. Enter N(o) to the question about replacing the cache battery.
9. Enter 2 for the install a controller or cache module option.
10. Enter 4 to exit FRUTIL.
11. Enter Y(es) to confirm intent to install the “other controller.” FRUTIL
quiesces the device ports and displays a message indicating that the controller
is being installed.
Caution: Wait for
FRUTIL
to quiesce the device ports—indicated by an “All
device ports quiesced” message. Failure to allow the ports to quiesce
can result in data loss. Quiescing can take several minutes.
Carefully align the controller in the appropriate guide rails. Misalignment can
damage the backplane.
Note: A countdown timer allows a total of 2 minutes to install the controller. After 2
minutes, “this controller” exits
FRUTIL
and resumes operations. If this happens, return
to step 7 and proceed.