HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Common Replacement Information and Procedures
87HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
3. Add the RAIDset on the “other controller” (see Figure 31).
Figure 31: Adding the RAIDset to the “other controller” and adding a new disk
4. Add the new disk, initialize it (see Figure 31), and then issue the SHOW
command (see Figure 32).
Note: Do not initialize the original members or the RAIDset.
Figure 32: Submitting the SHOW command
5. Add the RAIDset and member (n-1) with a new initialized disk on the “other
controller.”
Figure 33: Adding the RAIDsets and new member
The screen shown in Figure 34 on page 88 is displayed. In Figure 34, Instance
Code 02675201 indicates that the member moved to the failedset.
zBot> add disk disk20400 2 4 0
zBot> add disk disk50300 5 3 0
zBot> add disk disk60200 6 2 0
zBot> add disk disk10300 1 3 0
zBot> init disk10300
3 Members of the original RAIDset
New disk that is not a member
zBot> show disk10300
Name Type Port Targ Lun Used by
----------------------------------------------------------------------------
DISK10300 disk 1 3 0
COMPAQ BF00963643 3B05
Switches:
NOTRANSPORTABLE
TRANSFER_RATE_REQUESTED = 20MHZ (synchronous 20.00 MHZ negotiated)
Size: 17769177 blocks
zBot> add raidset r5 disk10300 disk20400 disk50300 disk60200
zBot> add unit d5 r5