HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Common Replacement Information and Procedures
88 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
Figure 34: Display indicating that the RAIDset is moved to another location
%EVL--zTop> --28-JAN-2004 16:35:39-- Instance Code: 02675201
< The device specified in the Device Locator field has been removed from the
RAIDset associated with the logical unit. The removed device is now in the
Failedset. The RAIDset is now in Reduced state. >
Template: 81.(51)
Occurred on 28-JAN-2004 at 16:35:39
Power On Time: 0. Years, 340. Days, 21. Hours, 31. Minutes, 40. Seconds
Controller Model: HSG80
Serial Number: ZG04808673 Hardware Version: 0000(00)
Software Version: V88P-0(FF)
Unit Number: 5.(0005)
Unit Software Version: 1.(01) Unit Hardware Version: 53.(35)
Retry Level: 1. Retries: 1.
Port: 1. Target: 3. LUN: 0.
SCSI Device Type: 0.(00)
Device ID: "BF00963643" Device Serial Number: "71355BKD"
Device Software Revision Level: "3B05"
SCSI Command Opcode: 0.(00)
Sense Data Qualifiers: 0.(00)
SCSI Sense Data:
Error Code: 112.(70) {current command execution}
Information field is valid
Segment: 0.(00)
Sense Key: 6.(06) UNIT ATTENTION
ILI: 0 EOM: 0 FM: 0
Information: 00000000
Additional Sense Length: 0.(00)
Command-Specific Information: 00000000
ASC: 160.(A0) ASCQ: 7.(07)
FRU: 0.(00) Sense-Key Specific: 000000
Instance Code: 02675201