HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Common Replacement Information and Procedures
92 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
7. Add a new disk to the array controller configuration with one of the following
commands:
ADD DISKS DISKXXXX P T L
or
RUN CONFIG
Note: If you submit the RUN CONFIG CLI command when a bad disk drive exists,
ACS skips the bad disk drive while running the RUN CONFIG command and reports
the following error:
DEVICE AT P1:T4:L0 failed initialization, Skipping
Device
8. Add a unit with the following command:
ADD UNITS DXXX DISKXXXX
9. Mount the disk to the operating system.
10. Restore the data from the backup.
Tip: Depending on the system load and the number of drives installed, you may need
to wait 1 to 5 minutes between the removal and installation of a replacement disk in
order for the replacement procedure to complete properly.
Tip: If at any time, disk drive errors occur and you must contact an HP service
representative, submit the SHOW DEVICE_ERRORS
FMU
command prior to
contacting an HP service representative. Submitting the SHOW DEVICE_ERRORS
FMU
command generates a report that assists the HP service representative in resolving
device problems. For additional details regarding the SHOW DEVICE_ERRORS
command, refer to the
HP StorageWorks HSG60 and HSG80 Array Controller and
Array Controller Software Troubleshooting Guide.
Replacing a storage unit with partitions
Storage containers that have partitions created on them present a unique
maintenance issue in that the partition may reside on one disk (JBOD) or across
several disks (RAID0, RAID 0+1, RAID5). Failure of any partition can require