HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Common Replacement Information and Procedures
94 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
Replacing a disk drive
Disk drive hot swapping is supported under the circumstances described below.
Abide by the following rules related to disk drive removal and disk drive insertion
into HSG80 subsystems.
Note: If you submit the RUN CONFIG CLI command while a bad disk drive exists,
ACS skips the bad disk drive while running the RUN CONFIG command and reports
the following error:
DEVICE AT P1:T4:L0 failed initialization, Skipping
Device
Tip: Consider the following initialization and troubleshooting tips:
If you are initializing a disk, HP recommends that you initialize the disk without any
partitions prior to initially placing it into use. If you are adding a new disk to an
array, and it is presented to a Microsoft Windows or Windows NT host, add the
new disk to the array first, and then initialize the disk using the INITIALIZE
container-name DESTROY_MBR CLI command. Doing this prevents the
creation of more than one partition on a disk. Refer to the
HP StorageWorks
HSG60 and HSG80 Array Controller and Array Controller Software Command
Line Interface Reference Guide
for additional information about the INIT DEVIC
DESTROY_MBR CLI command.
If you have a disk that was initialized at the container or device level using the
SAVE_CONFIGUATION switch, you can submit the ASSIGN storageset
LUN_WWID=xx CLI command to remove the SAVE_CONFIGURATION attribute
and reassign the unit its original WWID.
If you need specific information regarding disks in a subsystem, you can submit the
SHOW DEVICE_INFO ALL or SHOW DEVICE_INFO Dxxxx
FMU
command.
This command provides details regarding the disk port number, target number,
model number, firmware version, serial number, device flags, metadata version,
and SAVE_CONFIGURATION status. Refer to the
HP StorageWorks HSG60 and
HSG80 Array Controller and Array Controller Software Troubleshooting Guide
for
additional information about the SHOW DEVICE_INFO ALL and SHOW
DEVICE_INFO Dxxxx
FMU
commands.