HP StorageWorks HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide (AA-RV1RA-TE, March 2005)

FC Configuration Procedures
168 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide
Option 1 - View Adapters
The following example shows one JNI SBUS 64-bit Adapter and two JNI PCI
Adapters. The JNI SBUS adapter is configured for Arbitrated Loop and the JNI
PCI adapters are configured for Fabric mode. Note also that both PCI adapters are
communicating with the same Worldwide Port Name entities on the Fabric. The
RAID configuration employed is unknown.
Option 2 - Add an Adapter
Select Option 2 to be informed of and prompted for permission to scan the bus(es)
on the system and report any adapters not already listed. The steps that follow
when adding an adapter are self-explanatory.
Option 3 - Remove an Adapter
Select Option 3 to view a list of the adapters. You can then either choose to quit
the ’remove’ operation by pressing Enter or select an adapter by inputting the
adapter NN (numeric identification at the left in the list). The user must then
confirm that this adapter is to be removed from the list.
Option 4 - Modify an Adapter
Select Option 4, Modify an Adapter, to see a list of the adapters. To quit the
’modify’ action by pressing Enter or select an adapter to modify by entering the
NN (numeric identification at the left in the list).
NN Adapter # Control. M LN Targets
Port IDs ( WWPN ) Driver Path
1 fcaw0 fcaw L 16 64,65
/sbus@2,0/fcaw@2,0
2 fibre-channel 0 fca-pci F 16 64
5000-1fe1-0000-0d41
/pci@a,2000/fibre-channel@2
65 5000-1fe1-0000-0d42
3 fibre-channel 1 fca-pciF 16 64
5000-1fe1-0000-0d41
/pci@b,2000/fibre-channel@2
65 5000-1fe1-0000-0d42
-- Hit RETURN to continue --