HP StorageWorks HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide (AA-RV1RA-TE, March 2005)

FC Configuration Procedures
176 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide
5. At the servers, reconfigure the adapters to support loop. This is accomplished
with /opt/HPfcraid/bin/config.sh, Option 4, Modify
Adapters. This option allows the mode of the driver to be changed and the
Targets to be verified for the configuration. For each adapter that is used in
the changed configuration, this modify step must be repeated. For each server
in the changed configuration, this modify step must be repeated.
6. The changes from Step 5 require that the servers be rebooted (reboot --
-r) to reinitialize the drivers in the correct mode and acquire the new
entries/Targets from the sd.conf files as discussed above. Shutdown and
power-off the Sun server before rebooting. The adapters must be
power-cycled for reliable operation when changing from fabric to loop mode.
7. Using the format command, verify that the units of the subsystems are now
available.