HP StorageWorks HSG80 Enterprise/Modular Storage RAID Array Fibre Channel Solution Software V8.7A for Novell NetWare Release Notes
New Features
9Release Notes – HSG80 Enterprise/Modular Storage RAID Array Fibre Channel Solution
Software Version 8.7A for Novell NetWare
With the new switch enabled, drives in a normalized and redundant set that report
a SMART error are removed from that set. SMART errors reported by drives in a
non-redundant or non-normal set continue to be treated as recovered errors. If the
switch is disabled, all SMART errors are treated as recovered errors.
• Error Threshold for Drives—ACS now provides the ability to set limits for drive
errors. Once the limit is reached, the questionable drive is removed from any
redundant set it is a member of and put into the failed set. Errors counted are
medium and recovered errors. Hardware errors are not included in this count since
the drive fails immediately when a hardware error is encountered.
CLI Command Updates
The following CLI commands and switches were added or enhanced in ACS Version
8.7:
Host Connection Table Locking
SET controller CONNECTIONS_LOCKED
SET controller CONNECTIONS_UNLOCKED
ADD CONNECTIONS REJECTED_HOST
Selective Management Presentation
SET DISABLE_MANAGERS
SET ENABLE_MANAGERS
Linked WWIDs for Snap and Clone Units
ADD SNAPSHOT_UNITS USE_PARENT_WWID
SMART Error Drive Eject
SET controller SMART_ERROR_EJECT
Error Threshold for Drives
CLEAR_ERRORS DRIVE_ERRORS
SET DRIVE_ERROR_THRESHOLD
SHOW DRIVE_ERROR_THRESHOLD
See the HSG80 Array Controller ACS Version 8.7 CLI Reference Guide for complete
syntax details.