HSG80 ACS Solution Software V8.6 for Compaq OpenVMS Installation and Configuration Guide
5–6 HSG80 ACS Solution Software Version 8.6 for Compaq OpenVMS Installation and Configuration Guide
NOTE: Setting the SCSI version to SCSI-3 does not make the controller fully compliant with all
SCSI-3 standards. .
6. Assign an identifier for the communication LUN (also called the command console
LUN, or CCL). The CCL must have a unique identifier that is a decimal number in the
range 1 to 32767, and which is different from the identifiers of all units. Use the
following syntax:
SET THIS IDENTIFIER=N
Identifier must be unique among all the controllers attached to the fabric within the
specified allocation class.
7. Set the topology for the controller. If both ports are used, set topology for both ports:
SET THIS PORT_1_TOPOLOGY=FABRIC
SET THIS PORT_2_TOPOLOGY=FABRIC
If the controller is not factory-new, it may have another topology set, in which case
these commands will result in an error message. If this happens, take both ports offline
first, then reset the topology:
SET THIS PORT_1_TOPOLOGY=OFFLINE
SET THIS PORT_2_TOPOLOGY=OFFLINE
SET THIS PORT_1_TOPOLOGY=FABRIC
SET THIS PORT_2_TOPOLOGY=FABRIC
8. Set Allocation class to a decimal number between 0 and 999. The number must be
unique across the fabric. Set allocation class using the following syntax:
SET THIS ALLOCATION_CLASS=N
Restart the Controller
9. Restart the controller, using the following command:
RESTART THIS
10. Assign an identifier for the communication LUN (also called the command console
LUN, or CCL). The CCL must have a unique identifier that is a decimal number in the
range 1 to 32767, and which is different from the identifiers of all units. Use the
following syntax:
SET THIS IDENTIFIER=N
Identifier must be unique among all the controllers attached to the fabric within the
specified allocation class.