HSG80 ACS Solution Software V8.6 for Compaq OpenVMS Installation and Configuration Guide
Configuration Procedures 5–11
■ Restart the Controller.
■ Set Time and Verify All Commands.
■ Plug in the FC Cable and Verify Connections.
■ Repeat Procedure for Each Host Adapter.
■ Verify Installation.
1. Enter a
SHOW THIS command to verify the node ID:
SHOW THIS
See “Worldwide Names (Node IDs and Port IDs),” page 1–18, for the location of the
sticker.
The node ID is located in the third line of the SHOW THIS result:
HSG80> show this
Controller:
HSG80 ZG80900583 Software V8.6F-1, Hardware E11
NODE_ID = 5000-1FE1-0001-3F00
ALLOCATION_CLASS = 0
If the node ID is present, go to step 5.
If the node ID is all zeroes, enter the node ID and checksum, which are located on a
sticker on the controller enclosure. Use the following syntax to enter the node ID:
SET THIS NODE_ID=NNNN-NNNN-NNNN-NNNN nn
Where: NNNN-NNNN-NNNN-NNNN is the node ID and nn is the checksum.
2. If the controller is not new from the factory, enter the following command to take it out
of any failover mode that may have been previously configured:
SET NOFAILOVER
If the controller did have a failover mode previously set, the CLI may report an error.
Clear the error with this command:
CLEAR_ERRORS CLI
3. Enter the following command to remove any previously configured connections:
SHOW CONNECTIONS
A list of named connections, if any, is displayed.
4. Delete these connections by entering the following command:
DELETE !NEWCON01