HSG80 ACS Solution Software V8.6 for Compaq OpenVMS Installation and Configuration Guide

Configuration Example Using CLI 75
RESTART OTHER
RESTART THIS
SET THIS TIME=10-Mar-2001:12:30:34
RUN FRUTIL
Y
Plug serial cable from maintenance terminal into bottom controller.
NOTE: Bottom controller (B) becomes this controller.
RUN FRUTIL
Y
SET THIS MIRRORED_CACHE
NOTE: This command causes the controllers to restart.
SET THIS PROMPT=BTVS BOTTOM
SET OTHER PROMPT=BTVS TOP
SHOW THIS
SHOW OTHER
Plug in the Fibre Channel cable from the first adapter in host RED.
SHOW CONNECTIONS
RENAME !NEWCON00 RED1B1
SET RED1B1 OPERATING_SYSTEM=VMS
RENAME !NEWCON01 RED1A1
SET RED1A1 OPERATING_SYSTEM=VMS
SHOW CONNECTIONS
NOTE: Connection table sorts alphabetically.
Do you intend to replace this controller's cache battery? Y/N [Y]
Do you intend to replace this controller's cache battery? Y/N [Y]