HSG80 ACS Solution Software V8.6 for SGI IRIX Installation and Configuration Guide
5–20 HSG80 ACS Solution Software Version 8.6 for SGI Irix Installation and Configuration Guide
For example:
To assign unit D4 to DISK20300, use the following command:
ADD UNIT D4 DISK20300
Assigning a Unit Number to a Partition
To assign a unit number to a partition, use the following syntax:
ADD UNIT UNIT-NUMBER STORAGESET-NAME PARTITION=PARTITION-NUMBER
For example:
To assign unit D100 to partition 3 of mirrorset mirr1, use the following command:
ADD UNIT D100 MIRR1 PARTITION=3
Configuration Options
Changing the CLI Prompt
To change the CLI prompt, enter a 1- to 16- character string as the new prompt, according
to the following syntax:
SET THIS_CONTROLLER PROMPT = “NEW PROMPT”
If you are configuring dual-redundant controllers, also change the CLI prompt on the
“other controller.” Use the following syntax:
SET OTHER_CONTROLLER PROMPT = “NEW PROMPT”
NOTE: It is suggested that the prompt name reflect some information about the controllers. For
example, if the subsystem is the third one in a lab, name the top controller prompt, LAB3A and
the bottom controller, LAB3B.
Mirroring cache
To specify mirrored cache, use the following syntax:
SET THIS MIRRORED_CACHE