HSG80 ACS Solution Software V8.6 for SGI IRIX Installation and Configuration Guide
1–22 HSG80 ACS Solution Software Version 8.6 for SGI Irix Installation and Configuration Guide
If the StorageWorks Command Console (SWCC) will be used, the HSG80 Command
Console LUN must be enabled.
HSG80> SET THIS_CONTROLLER COMMAND_CONSOLE_LUN
1. After all of the settings have been made, restart both controllers by entering the
following command:
HSG80> RESTART OTHER_CONTROLLER
HSG80> RESTART THIS_CONTROLLER
2. Set the connection type by first examining the connections by entering the following
command:
HSG80> SHOW CONNECTIONS
3. In the following command substitute [CONNECTIONNAME] withthenamesshowninthe
output of the
SHOW CONNECTIONS command. Set the connections to SGI by typing:
HSG80> SET [CONNECTIONNAME] OPERATING __SYSTEM =SGI
4. Repeat Step 3 for each connection shown after entering the command in Step 2.
Fabric Setup
Ensure that the HSG80 controllers have been set correctly for fabric. Compare the settings
displayed by the CLI with those in Table 1–3. The current settings can be viewed by
entering the following command:
HSG80> SHOW THIS_CONTROLLER
If the HSG80 controller parameter settings displayed do not match those in the
Recommended Settings column in Table 1–3, the following CLI commands can be used to
alter their values.
Table 1–3 Controller Parameters and Recommended Settings
for Fabric
Controller Parameter Recommended Setting
PORT_1_Topology Fabric
PORT_2_Topology Fabric
This_Controller SCSI_Version SCSI-2
Other_Controller SCSI_Version SCSI-2