HSG80 ACS Solution Software V8.6 for SGI IRIX Installation and Configuration Guide
Preparing the Host System 3–7
Once the StorageWorks software has been installed, logical units may be created on the
RAID Array and configured into the system. These logical units can be created using the
SWCC Client or the CLI. In order to utilize Client to create logical units, Agent must first
be installed on the host SGI system. Chapter 4 contains details about Agent, and Appendix
B contains details about Client. Once the Agent and Client have been installed, the
following sections will guide you through the remaining steps in the configuration and
initialization process.
Host Device Initialization
New logical units created on the RAID Array with SWCC or the CLI must be initialized
and partitioned before they can be utilized by the Host operating system. The logical unit
will be recognized by the operating system after the logical unit has been created and the
system restarted. The following steps outline the process.
1. Using the CLI or the SWCC Client, create the logical units on the RAID Array.
2. Restart Irix according to the established local system administration procedures.
3. Once the bootstrap process has completed, log in to the system as the superuser (root).
4. Verify that host has located and configured the new RAID Array devices into the
operating system with the command:
# hinv -v
Copyright Compaq Computer Corp. 1994 - 2001. All rights reserved.
Restricted Rights: Use, duplication by the U.S. Government is subject to restriction as set forth in
subparagraph (c) (1) (ii) of DFARS 252.227-7013, or in FAR 52.227-19, or in FAR 52.227-14 Alt.III, as
applicable
Portions of this software are proprietary to and embody the confidential technology of Compaq Computer
Corporation. Possession, use, or copying of this software and media is authorized only pursuant to a valid
written license from Compaq or an authorized sublicensor.
Checking User...OK
Checking Irix Revision Level...OK
Checking that Host Adapter is installed and correctly configured...OK
Copying installation files to /usr/stgwks directory...OK
StorageWorks Software Installed
-- Hit RETURN to continue --