HSG80 ACS Solution Software V8.6 for SGI IRIX Installation and Configuration Guide
Preparing the Host System 3–11
[g]eometry [m]anufacturer_params [b]ootinfo
fx/label/set>
parameters
fx/label/set/parameters: Error correction = (enabled)
fx/label/set/parameters: Data transfer on error = (enabled)
fx/label/set/parameters: Report recovered errors = (enabled)
disabled
fx/label/set/parameters: Delay for error recovery = (enabled)
fx/label/set/parameters: Err retry count = (4)
fx/label/set/parameters: Transfer of bad data blocks = (enabled)
fx/label/set/parameters: Auto bad block reallocation (write) = (enabled)
fx/label/set/parameters: Auto bad block reallocation (read) = (enabled)
fx/label/set/parameters: Read ahead caching = (enabled)
fx/label/set/parameters: Write buffering = (disabled)
fx/label/set/parameters: Drive disable prefetch = (0)
fx/label/set/parameters: Drive minimum prefetch = (0)
fx/label/set/parameters: Drive maximum prefetch = (0)
fx/label/set/parameters: Drive prefetch ceiling = (0)
fx/label/set/parameters: Enable CTQ = (disabled)
enabled
fx/label/set/parameters: CTQ depth = (2) 3
fx/label/set/parameters: Read buffer ratio = (0/256)
fx/label/set/parameters: Write buffer ratio = (0/256)
* * * * * W A R N I N G * * * * *
about to modify drive parameters on disk C5P1! ok?
yes
----- please choose one (? for help, .. to quit this menu)-----
[para]meters [part]itions [s]giinfo
[g]eometry [m]anufacturer_params [b]ootinfo
fx/label/set>
----- please choose one (? for help, .. to quit this menu)-----
[sh]ow/ [sy]nc [se]t/ [c]reate/
fx/label>
..
----- please choose one (? for help, .. to quit this menu)-----
[exi]t [d]ebug/ [l]abel/ [a]uto
[b]adblock/ [exe]rcise/ [r]epartition/ [f]ormat
fx>
exit
label info has changed for disk C5P1. write out changes? (yes)
As Irix writes the disk label to the RAID Array, an error message is usually displayed on
the system console. The error message reads:
dks10d64: [Alert] Illegal Request: Illegal Field in CDB………
This message is caused by the Host adapter sending an illegal command to the RAID
Array. The error message can be ignored.