HSG80 ACS Solution Software V8.6 for Windows NT and Windows 2000 Installation and Configuration Guide

5–6 HSG80 ACS Solution Software Version 8.6 for Windows NT and Windows 2000 Installation and
Configuration Guide
NOTE: Setting the SCSI version to SCSI-3 does not make the controller fully compliant with all
SCSI-3 standards. .
6. Set the topology for the controller. If both ports are used, set topology for both ports:
SET THIS PORT_1_TOPOLOGY=FABRIC
SET THIS PORT_2_TOPOLOGY=FABRIC
If the controller is not factory-new, it may have another topology set, in which case
these commands will result in an error message. If this happens, take both ports offline
first, then reset the topology:
SET THIS PORT_1_TOPOLOGY=OFFLINE
SET THIS PORT_2_TOPOLOGY=OFFLINE
SET THIS PORT_1_TOPOLOGY=FABRIC
SET THIS PORT_2_TOPOLOGY=FABRIC
7. Set Allocation class to a decimal number between 0 and 999. The number must be
unique across the fabric. Set allocation class using the following syntax:
SET THIS ALLOCATION_CLASS=N
Restart the Controller
8. Restart the controller, using the following command:
RESTART THIS
9. Assign an identifier for the communication LUN (also called the command console
LUN, or CCL). The CCL must have a unique identifier that is a decimal number in the
range 1 to 32767, and which is different from the identifiers of all units. Use the
following syntax:
SET THIS IDENTIFIER=N
Identifier must be unique among all the controllers attached to the fabric within the
specified allocation class.
Set Time and Verify all Commands
10. Set the time on the controller by entering the following syntax:
SET THIS TIME=DD-MMM-YYYY:HH:MM:SS
11. Use the FRUTIL utility to set up the battery discharge timer. Enter the following
command to start FRUTIL:
RUN FRUTIL