HSG80 ACS Solution Software V8.6 for Windows NT and Windows 2000 Installation and Configuration Guide

Configuration Procedures 5–7
When FRUTIL asks if you intend to replace the battery, answer Y:
Do you intend to replace this controller's cache battery? Y/N [N] Y
FRUTIL will print out a procedure, but will not give you a prompt. Ignore the
procedure and press the Enter key.
12. Set up any additional optional controller settings, such as changing the CLI prompt.
See the
SET THIS CONTROLLER/OTHER CONTROLLER command in the Compaq StorageWorks
HSG80 Array Controller ACS Version 8.6 CLI Reference Guide for the format of
optional settings.
13. Verify that all commands have taken effect. Use the following command:
SHOW THIS
Verify node ID, allocation class, SCSI version, failover mode, identifier, and port
topology.
The following sample is a result of a
SHOW THIS command, with the areas of interest in
bold.
Controller:
HSG80 (C) DEC ZG09030200 Software V8.6F, Hardware 0000
NODE_ID = 5000-1FE1-0000-0000
ALLOCATION_CLASS = 1
SCSI_VERSION = SCSI-3
Not configured for dual-redundancy
Device Port SCSI address 7
Time: 10-Mar-1999:12:30:34
Command Console LUN is lun 0
(IDENTIFIER = 88)
Host PORT_1:
Reported PORT_ID = 5000-1FE1-0000-0001
PORT_1_TOPOLOGY = FABRIC (fabric up)
Address = 210313
Host PORT_2:
Reported PORT_ID = 5000-1FE1-0000-0002
PORT_2_TOPOLOGY = FABRIC (fabric up)
Address = 210513
NOREMOTE_COPY
.......