HSG80 ACS Solution Software V8.6 for Windows NT and Windows 2000 Installation and Configuration Guide

1–14 HSG80 ACS Solution Software Version 8.6 for Windows NT and Windows 2000 Installation and
Configuration Guide
Numbers of Connections
The number of connections resulting from cabling one adapter into a switch or hub
depends on failover mode and how many links the configuration has:
If a controller pair is in transparent failover mode and the port 1 link is separate from
the port 2 link (that is, ports 1 of both controllers are on one loop or fabric, and port 2
of both controllers are on another), each adapter will have one connection, as shown in
Figure 1–9.
If a controller pair is in transparent failover mode and port 1 and port 2 are on the same
link (that is, all ports are on the same loop or fabric), each adapter will have two
connections, as shown in Figure 1–10.
If a controller pair is in multiple-bus failover mode, each adapter has two connections,
as shown in Figure 1–11.