HSG80 ACS Solution Software V8.6 for Windows NT and Windows 2000 Installation and Configuration Guide

2–4 HSG80 ACS Solution Software Version 8.6 for Windows NT and Windows 2000 Installation and
Configuration Guide
Figure 2–1. PTL naming convention
The controller can either operate with a BA370 enclosure or with a Model 2200 controller
enclosure combined with Model 4214R, Model 4254, Model 4310R, Model 4350R,
Model 4314R, or Model 4354R disk enclosures.
The controller operates with BA370 enclosures that are assigned ID numbers 0, 2, and 3.
These ID numbers are set through the PVA module. Enclosure ID number 1, which assigns
devices to targets 4 through 7, is not supported. Figure 22 shows the addresses for each
device in an extended configuration.
Figure 2–2. PTL addressing in a configuration in a BA370 enclosure
1 02 00
LUN 00
Target 02
Port 1
CXO5851B
Controller A
Controller B
EMU
PVA 0
Cache B Cache A
10300102001010010000
20300202002010020000
30300302003010030000
40300402004010040000
50300502005010050000
60300602006010060000
123456
3
2
1
0
EMU
PVA 2
11100110001090010800
21100210002090020800
31100310003090030800
41100410004090040800
51100510005090050800
61100610006090060800
123456
11
10
9
8
EMU
PVA 3
11500114001130011200
21500214002130021200
31500314003130031200
41500414004130041200
51500514005130051200
61500614006130061200
123456
15
14
13
12
PTL location = Device port number = 3
Target number = 08
LUN = 00
Device port numbers
Target
numbers