HP StorageWorks 3000/5000 Enterprise Virtual Array connectivity 3.
Legal and notice information © Copyright 2007 Hewlett-Packard Development Company, L.P.
Version: 3.110 Description This document describes HP-UX operating system connectivity for HP StorageWorks 3000/5000 Enterprise Virtual Array (EVA3000/5000) controller software. A complete library of EVA3000/5000 documentation is available on the HP support website: http://www.hp.com/support/manuals Under storage, click Disk Storage Systems and then select either HP StorageWorks 3000 Enterprise Virtual Array or HP StorageWorks 5000 Enterprise Virtual Array under EVA Disk Arrays.
HP-UX OS version 11i v2.0 FCA (HBA) Clustering MC/ServiceGuard A.11.15, A.11.16, or later A6795A 2GB PCI Adapter firmware version (minimum) Adapter driver version (minimum) Native See HP-UX operating system install media Native See HP-UX operating system install media A9782A A9784A 2GB A5158A 1GB PCI AB465A 11i v3.0 HP Serviceguard 11.17.
NOTE: Dynamic multipathing support is not included. Prerequisites Required patches Table 2 lists the minimum patch revisions. Table 2 Patch revisions HP-UX version Minimum patch revisions 11i v1.0 Hardware Enablement Bundle HWEnable 11iB.11.11.0312.
Compatibility/Interoperability Switch support This release supports the Fibre Channel (FC) switches and firmware versions listed in the HP StorageWorks SAN design reference guide, available for download on the HP support website: http://www.hp.com/support/manuals Under storage, click Storage Networking, and then select HP StorageWorks SAN under HP StorageWorks SAN Solutions. NOTE: HP recommends that you do not mix switch firmware versions in your SAN.
Table 3 EVA-compatible HP-UX servers 11i v1.0 and 11i v2.0 supported servers PA RISC rp24xx B2600 C3700 C3750 J6750 Kx60 Kx70 Kx80 rp54xx Itanium rp74xx rp8400 V2200 V2600 V2250 V2500 SD16000 SD32000 SD64000 rx5670 zx6000 rx2600 zx2000 rx4640 rx7620 rx8620 SD Integrity 11i v3.
Secure Path version VCS 3.110 requires the latest version of Secure Path for your operating system. The current version of Secure Path for your operating system can be found at the following website: http://h18006.www1.hp.com/products/sanworks/secure-path/index.html Codeload usage When a maximally configured system is running at maximum load, Secure Path timing constraints make codeload functionality ineffective. The system may time-out before codeload is complete.
CAUTION: Persistent EVA overload may indicate an overloaded configuration and additional array host port resources may be required to match the configuration to the actual workload. Consult your local HP account or service representative for help to properly configure the EVA for your newly designed or existing configuration. High-availability environment recommendations In high-availability environments, under heavy I/O loads, you may experience I/O time-out conditions.