HP StorageWorks 3000/5000 Enterprise Virtual Array connectivity 3.
Legal and notice information © Copyright 2007 Hewlett-Packard Development Company, L.P.
Version: 3.110 Description This document describes Microsoft Windows operating system connectivity for HP StorageWorks 3000/5000 Enterprise Virtual Array (EVA3000/5000) controller software. A complete library of EVA3000/5000 documentation is available on the HP support website: http://www.hp.com/support/manuals Under storage, click Disk Storage Systems and then select either HP StorageWorks 3000 Enterprise Virtual Array or HP StorageWorks 5000 Enterprise Virtual Array under EVA Disk Arrays.
Table 1 Windows 2000 (32–bit) operating system specifications OS version Cluster support FCA (HBA) Adapter firmware version (minimum) 5.0 SP3, SP4 MSCS FC1143 FC1243 Adapter Boot BIOS version (minimum) Adapter driver version (minimum) Loaded from Driver 1.09 9.1.0.13 QMH2462 Loaded from Driver 1.16 9.1.0.13 LPe1105 2.50a8 3.00a2 5-5.20a10 FC2143 FC2243 2.10a7 1.70a3 5-5.20a10 FC2142SR FC2242SR 2.50a2 1.70a3 5-5.20a10 FC1142SR FC1242SR Loaded from Driver 1.09 9.1.0.
* Use this adapter firmware, BIOS, and driver for HSG80 and EVA controllers in the same SAN. Table 2 Windows Server 2003 (32–bit) operating system specifications OS version Cluster support FCA (HBA) Adapter firmware version (minimum) 5.2, 5.2 SP1 MSCS FC1143 FC1243 Loaded from Driver 1.09 QMH2462 Loaded from Driver 1.16 LPe1105 2.50a8 3.00a2 FC2143 FC2243 2.10a7 1.70a3 FC2142SR FC2242SR 2.50a2 1.70a3 FC1142 FC1242 Loaded from Driver 1.09 Adapter Boot BIOS version (minimum) 9.1.0.
OS version Cluster support FCA (HBA) Adapter firmware version (minimum) 5.2, 5.2 SP1 MSCS FCA2214 FCA2214DC Loaded from Driver BL20p G2 (FC Mezzanine Card) BL20p G3 (FC Adapter Card) Loaded from Driver BL25p (HPBALCF 105) BL45p (HPBALCF 105) Loaded from Driver BL30p (FC Balcony Card) BL35p (FC Balcony Card) Loaded from Driver BL20p G3 (E-FC Adapter Card ) BL25p (E-FC Balcony Card) BL45p (E-FC Balcony Card) 6 Adapter Boot BIOS version (minimum) 1.45 Adapter driver version (minimum) 9.1.0.
Table 3 Windows Server 2003 (64–bit) operating system specifications OS version Cluster support FCA (HBA) 5.2 5.2 SPI MSCS Adapter firmware version (minimum) Adapter Boot BIOS version (minimum) Adapter driver version (minimum) A8002A A8003A 2.50a6 3.11a5 6-1.20a7 AE311A AD300A Loaded from Driver 1.05 9.1.3.16 AB379A AB429A Loaded from Driver 1.05 9.1.0.18 AD167A AD168A 2.10a7 3.11a4 6-1.11x1 6-5.20a9 6-1.11x1 AB232A AB466A AB467A 1.91a1 3.10a6 A7298A 1.91a1 3.10a6 6-5.20a9 6-1.
Table 4 Windows Server 2003 x64 operating system specifications OS version Cluster support FCA (HBA) Adapter firmware version (minimum) 5.2 5.2 SPI MSCS FC1143 FC1243 8 Adapter Boot BIOS version (minimum) Adapter driver version (minimum) Loaded from Driver 1.09 9.1.0.18 QMH2462 Loaded from Driver 1.16 9.1.0.18 LPe1105 2.50a8 3.00a2 7-1.11x1 FC2143 FC2243 2.10a7 1.70a3 7-1.11x1 FC2142SR FC2242SR 2.50a2 1.70a3 7-1.11x1 FC1142 FC1242 Loaded from Driver 1.09 9.1.0.
Enhancements This release includes the following enhancements: • Support for EVA3000/5000 controller software 3.110 • Support for the latest Emulex and QLogic drivers NOTE: This release, which includes Emulex driver 5.10a10 and QLogic driver 9.0.0.13, does not support the configuration where a single Windows host has access to an EVA and an MA (HSG80) array simultaneously. The HBA revisions must remain at 4.82a16 for Emulex drivers or 8.2.0.73 for QLogic drivers.
• Intel-based ProLiant X86, and ProLiant Blade servers • Intel-based EM64T ProLiant servers and Blade servers • HP Integrity servers HP StorageWorks Storage System Scripting Utility The latest version of the HP Storage System Scripting Utility (SSSU) is available on the software downloads website: http://www.hp.com/support/downloads Under storage, click Storage software, and then select HP StorageWorks Command View EVA Software under Storage Device Management Software.
5. Locate the Pending Timeout value and change it to 360. 6. Click OK. Host considerations Windows 2000 and Windows Server 2003 notes Drive-letter remapping can occur in the following situations and it can affect access to data by programs you may need to run: • Replacing one server with another. • Replacing an FC HBA in one of your systems. During such a system or adapter changeover, be sure to manually remap drives to drive letters using Disk Manager. This restores proper access to your data.
Windows 2000 dynamic disk snapshots and snapclones The use of snapshots and snapclones in HP SANs is not supported in a Windows 2000 environment if the snapshot or snapclone is presented to the same Windows 2000 host as the LUN from which the snapshot or snapclone was created. Snapshot and snapclone are features of the HSG80 and HSV110 controller-based HP storage systems. All dynamic disks on a system have information in their metadata about the other dynamic disks that exist on the system.