HP StorageWorks 3000/5000 Enterprise Virtual Array connectivity 4.
Legal and notice information © Copyright 2007 Hewlett-Packard Development Company, L.P.
Version: VCS 4.100 Description This document describes HP-UX operating system connectivity support for HP StorageWorks 3000/5000 Enterprise Virtual Array (EVA3000/5000) controller software. A complete library of EVA3000/5000 documentation is available on the HP support website: http://www.hp.com/support/manuals. Under storage, click Disk Storage Systems, and then select either HP StorageWorks 3000 Enterprise Virtual Array or HP StorageWorks 5000 Enterprise Virtual Array under EVA Disk Arrays.
Table 1 Operating system specifications HP-UX version 11iV1.0 Clustering Fibre Channel adapter Adapter firmware HP ServiceGuard A.11.
HP-UX version 11iV2.0 Clustering Fibre Channel adapter Adapter firmware HP ServiceGuard A.11.
HP-UX version 11iV3.0 Clustering Fibre Channel adapter Adapter firmware HP ServiceGuard A.11.16 or later AB378B 4Gb PCI Native AB379B 4Gb PCI Native AD193A 4Gb Native AD194A 4Gb Native AD378A Native AD379A Native A6826A 2Gb PCI Native AB465A 2Gb PCI Native A9784A 2Gb Native A9782A 2Gb Native A6795A 2Gb PCI Native A5158A 1Gb PCI Native NOTE: Direct-connect is not supported.
Prerequisites Multiple-path support Multiple-path capability is integrated into the HP-UX system. No additional software is required to achieve high-availability, multiple-path capability. You have the following options: • Native multipathing functionality • HP-UX PVLinks multipathing solutions For more information about PVLinks, see your HP-UX operating system documentation. For more information about multipath options, see the HP multipath website: http://h18006.www1.hp.
Supported servers Table 2 lists the EVA-compatible HP-UX servers. Table 2 EVA-compatible HP-UX servers PA Risc Itanium® rp24xx rp54xx rp34xx rp44xx rp7400 rp7420 rp84xx rp7410 L1000/2000 Kx60 Kx70 Kx80 rx26xx rx46xx rx56xx zx2000 zx6000 SD Integrity rx16xx rx1620 rx76xx rx86xx HP StorageWorks Storage System Scripting Utility The latest version of the Storage System Scripting Utility (SSSU) is available on the software downloads HP website: http://www.hp.
Logical Volume Manager Before you create snapshots or snapclones of a device that is managed by Logical Volume Manager (LVM), be sure to properly configure LVM. After creating a snapshot or snapclone of a physical volume, always run vgchgid(1M) to break the association between the volume group and the snapshot or snapclone. Otherwise, snapshots or snapclones appear to LVM as an alternate path to the original physical volume.