HP P6000 1GbE iSCSI and 10GbE iSCSI/FCoE Firmware Release Notes HP Part Number: 5697-3242 Published: March 2014 Edition: 6
© Copyright 2012–2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.
Contents Version....................................................................................................................................4 Description..............................................................................................................................4 Rebranding.........................................................................................................................4 Update recommendation.....................................................................
Version (iSCSI) MEZ50-3_2_2_12 and (iSCSI/FCoE) MEZ75-3_2_2_12, additional support for FlexFabric 5900AF and 5900CP switch interoperability, Windows 2012, HP EVA P6000 XCS 11200000 controller software, and Command View 10.3. Description The information in this document is not provided elsewhere. HP recommends to read this information thoroughly.
Documentation location Latest editions of documentation can be downloaded from the HP website http://www.hp.com/ support/manuals as follows: Click Disk Storage Systems under Storage, and then select HP P6000 Enterprise Virtual Array Systems under P6000/EVA Disk Arrays.
• Microsoft Windows 2012 LOGO conformance test failure, where a persistent reservation generation in the PERSISTENT RESERVE IN SCSI command parameter data field was not incremented when a Microsoft Windows 2012 iSCSI or FCoE initiator PREEMPTed its own reservation.
• iSCSI/FCoE module FCoE presented target mappings sometimes fail to recover after power is cycled. • iSCSI and iSCSI/FCoE modules support capture files are sometimes incomplete. Operational notes Aborts may be observed by Linux iSCSI initiators when a iSCSI target queue-full under run condition response occurs. This occasional abort condition, which will result in a retried operation, is an expected response.
To extend the timeout period, under HKLM\System\CurrentControlSet\services\Disk, set the TimeOutValue entry to REG_DWORD = 120. Method 2 Make the change to the registry, or cut and paste the following lines to a text file named: tcp1323opts.reg: REGEDIT4 [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\Tcpip\Parameters] "Tcp1323Opts"=dword:00000002 Double-click the tcp1323opts.reg file to add the changes to the registry for the iSCSI initiator.