HP StorageWorks Enterprise Virtual Array 3000/5000 to 4100/6100/8100 Upgrade Assessment (5697-6985, July 2007)

About this doc ument
The EVA4100/610 0/8 1 00 uses active/active controller failover behavior instead of the active/passive
controller f
ailover behavior in VCS 3.xxx. The change to active/a ctive will impact most host
congurati
ons. The impact of this change may involve replacing HBAs and drivers, installing new
multi-path
ing software, and re-establishing the correct paths to the storage system LUNs.
Usethisdocumenttoassess:
The impact of upgrading your EVA3000/5000 to an EVA4100/6100/8100.
Your curre
nt host conguration to determine the changes required to suppor t active/active
(if applic
able).
What storage system components may have to be replaced during the upgrade.
NOTE:
You must b
e running VCS 3.028 or later, or VCS 4.007 or later to upgrade to an
EVA4100/
6100/8100.
You must perform this assessment on any host connected to the storage system you are considering
upgrading. Any host connected to an EVA4100 /6100/8100 must be congured to support
active/active I/O.
This upgrade procedure is used when upgrading to EVA4100/6100/8100 controllers. All upgraded
contro
llers must have XCS 6.110 or later installed.
Intended audience
This document is intended for customers who are considering upgrading an HP StorageWorks
EVA3000/5000 to an EVA4100/6100/8100.
Review suppor ted host conguration information
Before beginning the assessment, review the supported host conguration information for the applicable
operating systems. This information is contained in a series of connectivity release notes—one for each
supported operating system.
Download the connectivity release notes for each operating system you are using from the following
website:
h
ttp://www.hp.com/support/ma nuals
Select Disk Storage Systems under Storage, and then select HP StorageWorks 410 0/610 0/81 00
Enterprise Virtual Arrays under EVA Disk Arrays.
HP StorageWorks Enterprise Virtual Array 3000/5000 to 4100/6100/8100 upgrade assessment