HP StorageWorks 4x00/6x00/8x00 Enterprise Virtual Array updating product software guide (XCS 6.200) (5697-7958, February 2009)

2 Pre-upgrade tasks
There are a number of necessary tasks that can be performed prior to beginning the upgrade. Performing
these tasks prior to, rather than during, the upgrade minimizes the time required to perform the XCS
upgrade procedure.
The required tasks differ depending on your system conguration. They focus on upgrading components
to ensure they meet the supported conguration for XCS 6.200. Table 4 provides a checklist so you
can track your progress as you perform these pre-upgrade tasks.
Table 4 XCS 6.200 Pre-upgra de task chec klist
Checking current software versions,page15
Time required: 1015 minutes
When to perform: Any time prior to the upgrade
Check versions of all applicable installed management software.
Checking the storage system hardware,page17
Time required: 15 2 0 m i n u te s
When to perform: 1–2 weeks prior to the upgrade. Provide enough time to order and replace any failed
components.
Check hardware status using HP Command View EVA.
Check hardware components in the Unmappable Ha rdware folder.
Replace hardware as needed.
Checking and upgrading your SAN infrastructure, page 18
Time required: Varies depending on how many hardware and software components require replacement
or upgrade
When to perform: Any time prior to the upgrade
Things you will need:
Connectivity release notes. See Required documentation”onpage11.
SAN Visibility tool. See Collecting SAN conguration data using SAN Visibility on page 18
Verify all host HBAs and drivers are supported.
Verify Fibre Channel switch rmware is supported.
Upgrade unsupported components as necessar y.
Selecting an appropriate time to perform an online upgrade, page 25
Time required: Varies depending on how long it will take to gather I/O data
When to perform: Any time prior to the upgrade
Run HP Command View EVAPerf to gather I/O data.
Analyze data to identify a time period that meets the I/O criteria.
Managing host I/O timeouts for an online upgrade, page 29
Time required: Varies depending on number of hosts
When to perform: Any time prior to the upgrade
Determine if any host LUN timeouts have been changed from their defaults.
Reset any changed LUN timeout parameters to a minimum of 60 seconds.
Managing application I/O timeouts for an online upgrade,page32
Time required: Varies depending on number of applications
When to perform: Any time prior to the upgrade
Determine if any applications have timeouts set to more stringent values than the host LUN timeouts.
Change application timeout parameters to host LUN timeout values.
HP Stora g eWorks 4x00/6x00/8x0 0 Enterprise Virtual Array updating product software guide (XCS 6.200)
13