HP StorageWorks 4x00/6x00/8x00 Enterprise Virtual Array updating product software guide (XCS 6.200) (5697-7958, February 2009)

4. Select Launch Default M ail Client. The location of the report is displayed.
5. Manually at tach the raw report created and send the report to the following e-mail address:
SAN_Visibility@hp.com
The report will be processed and the formatted report retu rned to you within one business day.
6. When you rec eive the formatted report, save i t to a temporary location on the management server.
Reading the report
1. Locate the returned report le and double-click on it. The contents are extracted and copied to
alocalfolder
. If you used the d efault location during installation, this will be in the \Program
Files\Hewle
tt-Packard\HP SANVisibility\ExtractedProcessReports folder .
2. Select the report folder a nd double-click on the index.html le to open the report in your browser.
3. In the left navigation pane, click High Level Fabric Summa ry.
The High Leve
l Fabric Summary window opens. See Figure 6.
4. For each swi
tch, compare the indicated rmware (FW) version to the switch rmware supported by
XCS 6.200. This information is included in Part II. Fabric infrastructure rules of the HP StorageWorks
S AN design reference guide.SeeTable 3 on page 11 for the link to this document. If the rmware is
notattheindicatedversionorlater,upgradethermware .
5. For each HBA, comp are the indicated driver and rmware versions to the versions supported by
XCS 6.200. This information is included in the appropriate HP StorageWorks 4x00/6x00/8x00
Enterprise Virtual Array 6.2A or later connectivity release notes. See Table 3 on page 11 for the link
to these documents. If the rmware is not at the indicated version or later, upgrade the rmware.
24
Pre-upgrade tasks