HP StorageWorks 4x00/6x00/8x00 Enterprise Virtual Array updating product software guide (XCS 6.200) (5697-7958, February 2009)

discovery_threads=1
To check or set Linux parameters, use the set_parm executable found in the /opt/hp/<driver-
specific> directory. When executed, the options to change timeout values are displayed.
NOTE:
The timeout values must be increased for Emulex single path (without multipath support) and QLogic
single path being used in the environment. This is not only important for online upgrades but for
general data integrity.
Online controller rmware upgrades are supported with Linux boot devices.
Solaris
Solaris supports online controller upgrades with the following driver timeouts:
Sun Drivers (qlc or emlxs): 60 seconds
QLogic (qla2300) : 60 seconds
Emulex (lpfc): 60 seconds
Checking or changing timeouts
For Sun drivers, add the following lines to /etc/system le:
set sd:sd_io_time = 60
set ssd:ssd_io_time = 60
For QLogic, edit the /kernel/drv/qla2300.conf le and change the hbax-link-down-timeout
value to 60 as follows:
hba0-link-down-timeout=60;
For Emulex, edit the /kernel/drv/lpfc.conf le and change the linkdown-tmo value to 60
as follows:
linkdown-tmo=60;
Tru64
Tru64 has a 60 second timer for m e d ia command timeouts. In most cases, up to 5 retries can o ccur within
the kernel's I/O stack, which results in a 5–6 minute window before I/O is returned to the le system. No
changes should be made to any Tru64 settings when performing an online rmware upgrade.
Online controller rmware upgrad es are supported in Trucluster 4–node environments where the EVA is
the cluster boot device.
OpenVMS
The limit for LUN timeout is 120 seconds.
NOTE:
OpenVMS handles the controller reboot seen at the conclusion of the rmware update process. Disks on
the controller display a Mount Verify status during the controller reboot but regain Mounted status and
resume I/O operations upon the completion of the controller reboot. No changes need to be made to
any OpenVMS default settings when performing an online rmware upgrade.
Online controller rmware upgrades are supported in OpenVMS cluster environments where the EVA is
the clus
ter boot device.
HP Stora g eWorks 4x00/6x00/8x0 0 Enterprise Virtual Array updating product software guide (XCS 6.200)