HP StorageWorks 4x00/6x00/8x00 Enterprise Virtual Array updating product software guide (XCS 6.200) (5697-7958, February 2009)

1. Ensure that:
The software icons for HP Command View EVA
, HP Command View EVAPerf ,and/orHP
Storage System Scripting Utility
appear on the desktop.
If you installed the software suite on an SMA, the HP Command View EVA icon does not appear
on the desktop.
The software is available from the Start m enu (for example, Start > Programs > HP Command
View EVA).
If you installed the software suite on an SMA, the software is not ava ilable from the Start menu.
Go to Add/Remove Programs and make sure the applicable software components are listed:
HP StorageWorks Command View EVA software suite
HP StorageWorks Command View EVA
HP StorageWorks Command View EVA Performance Monitor
•HPStorageWorksSMI-SEVA
•HPStorageWorksSMI-SCIMOM
NOTE:
HP Storage System Scripting Utility is not listed in Add/Remove Programs.
2. Run HP Command View EVA.
3. Verify the display of storage system resources in the interface. In the Navigation pane, click
Hardware and verify the following:
New, uninitialized arrays appear as uninitialized storage systems.
Previously initialized arrays appear with their previous names and correct status. (Select each
storagearraytoviewthePropertieswindow.)
Previous disk groups, hosts, virtual disks, and other resources appear in the Navigation pane.
If information is not displayed properly, it may be necessary to cong ure your browser settings. See HP
StorageWorks Command View EVA installation guide for more information.
Upgrading browsers and JREs
Estimated time to complete: 1020 minutes
When to perform: Any time prior to the upgrade
Ensure that you are using a supported browser and JRE. HP Command View EVA may not work correctly
with an unsupported browser.
TheJREisnotusedbyHPCommandViewEVA,butitisneededforHPReplica-
tion Solutions Manager. It is a lso required for WEBES and SAN Visibility. See
Upgrading HP Replication Solutions Manager (optional) on page 36 for more information.
For complete information on suppor ted browsers and JREs, see the "Browsers and JRE
support" table in the HP StorageWorks Enterprise Virtual Array compatibility reference.See
Required documentation”onpage11forthelinktothisdocument.
NOTE:
If you need to update the browser version on remote computers, do so after you have upgraded to HP
Command View EVA 8.0.1.
Upgrading to WEBES 5.2
Estim
ated time to complete: 1020 minutes
34
Pre-upgrade tasks