HP StorageWorks 4x00/6x00/8x00 Enterprise Virtual Array updating product software guide (XCS 6.200) (5697-7958, February 2009)

When to perform: Any time prior to the upgrade
WEBES is optional diagnostic monitoring software. If WEBES is currently installed, it must be upgraded
to version 5.2, which is required with HP Command View EVA 8.0.1. To download the W EBES 5.2
software kit, go to the following website:
h
ttp://h18023.www1.hp.com/support/svctools/webes/
Archiving and clearing the err or log
Before upgrading WEBES, perform these steps to archive and clear the error log. If WEBES is installed and
running when you clear the log, stop the Dire ctor process before proceeding. See the WEBES User Guide
for information on stopping the Director. Also, do not stop and restart any Windows system processes.
NOTE:
You can upgrade WEBES without clearing the error log. However, the initial scan of event data may
take longer if the log is not cleared rst.
1. Open the event viewer.
Windows 2000: Select Start > Programs > Administrative Tools > Event Viewer.
•WindowsServer2003:SelectStart > Program s > Administrative Tools > Event Viewer.
Windows XP: Select Sta rt > Control Panel > Performance and Maintenance > Administrative
Tools > Event Viewer.
2. For events analyzed by the System Event Analyzer (SEA), follow step a” on a Pentium server or step
b”onanIntegrityserver.
a. Pentium: Clear the application event log:
Go to the Application Log. SEA does not p rocess events from any other Windows event log.
Select Application in the left pane of the event viewer window.
b. Integrity: Clear the system event log:
Go the System Log. SEA does not process events from any other Windows event log.
Select System Log intheleftpaneoftheeventviewerwindow.
3. Clear all events by selecting Action > Clear all Events.
NOTE:
Before the existing events are cleared, you are prompted to save them rst. Be sure to select
Yes to save these events to a le. You can analyze these saved events at a later time.
4. Closetheeventviewer.
Upgrading WEBES
This procedure applies when upgrading to W EBES 5.2 from an existing version of WEBES that is within
two versions of 5.2. For example, WEBES 5.2 can be upgraded when either version 4.5 or 5.1 is
installed, but not if version 4.4.3 or earlier is installed. If an upgrade is attempted on a version of WEBES
that is too old, you will be told to uninstall the existing version, and the upgrade will not proceed.
If WEBES is already uninstalled or was never installed, see the WEBES Installation Guide.
Upgra
ding lets you preserve your c onguration and state data. Be aware that upgrading uninstalls the
olde
r version of WEBES and installs the newer version. The upgra de does not patch or replace certain
les
, as was the case with WEBES Service Packs.
Whenever a version of WEBES is already installed that is capable of being upgraded, the WEBES kit
informs you that the older version was detected and prompts you about upgrading.
HP Stora g eWorks 4x00/6x00/8x0 0 Enterprise Virtual Array updating product software guide (XCS 6.200)