HP StorageWorks 4x00/6x00/8x00 Enterprise Virtual Array updating product software guide (XCS 6.200) (5697-7958, February 2009)

Before you upgrade any storage system in an HP Continuous Access EVA relationship, ensure that
all storage systems in the storage network are running the same version of controller software.
This will ensure that when you upgrade one storage system, the storage n et work will have only
two versions of controller software. You cannot have more than two versions in an HP Continuous
Access EVA environment.
During the time that the HP Continuous Access EVA storage systems are running different controller
software versions, you cannot make any conguration changes to your storage systems.
You must perform the necessary upgrades to the storage systems in the HP Continuous Access
EVA relationship within sixty d ays (1440 hours) to make all controller software versions the same.
CAUTION:
In an HP Continuous Access EVA environment, do not begin the upgrade until the following conditions
are met. If you attempt to upgrade the controllers before the following conditions are met, controller
operation will fail.
Ensure that no DR group is logging, merging, or copying. Furthermore, none of the DR groups can
be in a failsafe locked state.
1.
Click the DR group icon in the Navigation pane.
2.
Check the Log state in the DR Group Properties window.
Ensure the connection between the storage systems is not compromised or failed.
1.
Click the Data Replication folder in the Navigation pane.
2.
Check the Connection State in the Data Replication Folder Properties window.
All E VA storage systems must be running normally with fully functional controller pairs.
After upgrading the rst storage system (for example, the source), wait at least three minutes and no
more than one week before upgrading the second storage system. Ensure the preceding conditions
aremetonthesecondsystem.
Upgrading disk d rive rmware in an HP Continuous Access EVA environment
When upgrading disk drive rmware in an HP Continuous Access EVA environment, the following
requirements must be met. See HP StorageWorks Continuous Access EVA implementation guide for
more information.
Verify that all DR groups are not failsafe mode enabled or in the failsafe locked state (DR group
failsafemodeshouldbedisabled).
Suspend replication and disable the intersite link or modify zoning to isolate the source array
from the destination array.
Upgrade the disk drive rmware on the destination array.
Re-establish intersite link communication between the arrays and resume replication, allowing
the DR g roup merges to complete.
Perform site failover.
Suspend replication and disable the intersite link or modify zoning to isolate the source array
from the destination array.
Upgrade the disk drive rmwareonthenewdestinationarray(beforesitefailover,thiswas
the source array).
Re-establish intersite link communication between the arrays and resume replication, allowing
the DR g roup merges to complete.
Per form site failback.
Saving storage system conguration information
Estimated time to complete: 10–15 minutes
When to perform: As close as possible to the upgrade