HP StorageWorks 4x00/6x00/8x00 Enterprise Virtual Array updating product software guide (XCS 6.200) (5697-7958, February 2009)
3 Upgradin g the Enterpr ise Virtu al
Array
The following steps g uide you throug h the process of upgrading the system software. Ensure that you
follow them carefully and in the specified order. Table 9 on page 41 provid es a checklist so you can
track your progress as you perform the upgrade. Make sure you have all the items indicated before
beginning the upgrade.
Table 9 Upgrade task checklist
Step 1. Checking the health of the Enterprise Virtual Array,page42
Time required: 20–30 minutes
− HP Command View EVA indicates no hardware problems
− No hardware components in the Unmappable Hardware folder
− No critical events entered in the controller event log within the last 48 hours
− Storage system configuration is stable and no configuration changes have been made within the last 48
hours
Step 2. Disabling ISEE, page 45
Time required: 10–15 minutes
− Disable ISEE (if used).
Step 3. Clea
ring storage system passwords,page45
Time requir
ed: 10–15 minutes
− Clear the O
CP password.
− Disable pa
ssword access in HP Command View EVA .
Step 4. Halting all host access to the storage system for an offline upgrade (optional),page46
Time required: Varies by host. Must be performed for each host accessing the storage system
− Halt all applications accessing the storage system.
− Stop all I/O to the storage system.
Step 5. Upgrading controller firmware to XCS 6.200,page46
Time required: 25–30 minutes
Things you will need:
• HP StorageWorks EVA 4x00/6x00/8x00 6.2 controller software
− Upgrade XCS firmware to version 6.200.
Step 6. Upgrading disk drive firmware,page51
Time requi
red: Varies depending on the number of disk drives that must be upgraded. It c an take 30 seconds
to 3.5 minu
tes per drive.
Things you
will need:
• Disk driv
e code bundled image fi le, which can be downloaded from the following website:
h
ttp://www.hp.com/support/evadiskfirmware
− Download the disk drive fi rmware file.
− Upgrade the disk drive firmware.
HP Stora g eWorks 4x00/6x00/8x0 0 Enterprise Virtual Array updating product software guide (XCS 6.200)