HP StorageWorks 4x00/6x00/8x00 Enterprise Virtual Array updating product software guide (XCS 6.200) (5697-7958, February 2009)

3. Using HP Command View EVA, examine the controller event log and check for any critical events.
a. Select the icon of the storage system you want to upgrade in the Navigation p ane.
b. Click View Events.
TheViewEventspageopens.
c. Click Controller Event Log.
The Controller Events page opens in a new browser window.
d. Check the Severity eld to determine if any unexpected Critical events
have occurred within
the last 48 hou rs.
The most recent 400 events are displayed. If more than 400 events have occurred within the last
48 hours, use the Display Range box to select the preceding events.
Figure 12 Controller Events (Initi alized system) page
e. If Critica l events have occurred within the last 48 hours, perform the steps outlined in the
corre ctive action codes to correct the problems. In some cases, it may be ne c essary to call your
HP-authorized service representative to xtheproblem.
CAUTION:
If any critical events have occurred within the last 48 hours, do not proceed with the
upgrade until the situation has been resolved.
44
Upgrading the Enterprise Virtual Array