HP StorageWorks 4x00/6x00/8x00 Enterprise Virtual Array updating product software guide (XCS 6.200) (5697-7958, February 2009)

Figure 18 Verif ying XCS version after upgrading
Step 6. Upgrading disk drive rmw are
Estimated time to complete: Varies depending on the number of disk drives that require upgrading and the
I/O load on the storage system. It can take 30 seconds to 3.5 minutes per dri ve to upgrade the rmware.
The rmware on all disk drives can be upgraded online.
Although it is not required that the disk drive rmware be upgraded at the same time as the system
software, it is strongly recommended that you perform the two tasks together. The disk drive rmware
supplied with the system software upgrade complements the operation of the controller rmware and for
the best results the two should be used together.
You will need the correct disk drive rmware bundled image le to update the drive rmware. The disk
drive rmwar e le can be downloaded from the following website:
h
ttp://www.hp.com/support/evadiskrmware
Be sure to observe the following cautions when upgrading disk drive rmw are.
CAUTION:
Do not power off any components or perform controller resynchs or reboots during an upgrade.
Do not perform HP Continuous Access EVA copy/merge activities across sites, site failovers, cloning,
or grouping or ungrouping of disks du ring an upgrade.
Do not add to or remove members from DR groups during upgrade.
Ensure that you upgrade the di s k drive rmware after you upgrade the storage system software.
HP Stora g eWorks 4x00/6x00/8x0 0 Enterprise Virtual Array updating product software guide (XCS 6.200)
51