HP Fabric OS 6.2.2f Release Notes (5697-1756, February 2012)

Table 9 Fabric OS 6.2.1a closed defects (continued)
Fixed in Fabric OS 6.2.1aSMI failed to discover all switches over EX_Port after hafailover, and
reports LOGIN FAILED after the GPL2 query targeted to the translate
domain is rejected.
Fixed in Fabric OS 6.2.1aSFP power supply values are not displayed correctly after doing a
nondisruptive firmware upgrade to Fabric OS 6.2.1.
Workaround prior to update: Executing
the same command again shows the
correct values.
Fixed in Fabric OS 6.2.1aHigh CPU load from DCFM doing supportsave causes the port to go
offline with a laser FLT/link reset.
Fixed in Fabric OS 6.2.1aName server database counts do not match for Fabric OS 6.2.1 and M-EOS
9.9.0 switches in the same fabric, so the host cannot see the device. This
occurs when an HBA capable of an RHBA command and an M-EOS switch
are in the same fabric.
Fixed in Fabric OS 6.2.1aThe host cannot see the device due to a login failure with a non-FC standard
value (0x0000EF) to the name server, when the switch has port alpa also
enabled in interopmode 2.
Fixed in Fabric OS 6.2.1aWith Fabric OS 6.2.1 in a logical switch setup, a segmentation fault/core
dump occurs after configdefault.
Fixed in Fabric OS 6.2.1aHP StorageWorks DC SAN Director panics due to termination of msd during
fabric reconfiguration while doing switchdisable, agshow,
switchenable loop, in a fabric with an Access Gateway device with
more than 56 switches.
Fixed in Fabric OS 6.2.1aA small memory leak occurs when multiple simultaneous MIB WALK queries
are performed.
Fixed in Fabric OS 6.2.1a96-bit licenses disappear from the HP StorageWorks 8/80 SAN Switch
due to a race condition, even when there are no fabric changes in the
environment.
Fixed in Fabric OS 6.2.1aMerging an M6140 M-EOS switch into a Fabric OS switch fabric causes
a Fabric OS switch to panic.
Fabric OS 6.2.1b fixes
Table 10 (page 40) lists defects closed in the Fabric OS 6.2.1b firmware release. In addition to
including all fixes from the 6.2.0x, 6.2.1, and 6.2.1a releases, it contains all fixes included in the
5.3.2c, 6.1.2b, and 6.2.0g releases.
Table 10 Fabric OS 6.2.1b closed defects
SolutionClosed defect summary
Fixed in Fabric OS 6.2.1bSwitch panic occurs due to an out-of-memory condition when a management
application performs repeated FCR LUN emulation queries via SMI, or when
polling a switch whose password has changed multiple times.
Workaround prior to update: Disable SMI
agents.
Fixed in Fabric OS 6.2.1bHP StorageWorks DC SAN Director panicked and rebooted after fwshow
--disable --port command.
Fixed in Fabric OS 6.2.1bSegmentation fault causes a CALD panic in the fabric when the switch
running Fabric OS 5.2.x sends an internal query to directors that were not
properly set up to handle switches with more than 256 ports.
Fixed in Fabric OS 6.2.1bSwitch panic is triggered by size-64 kernel message buffer being used up
in a virtual fabric with logical ISL configured.
Workaround prior to update: Configure
only DISLs between switches.
40