HP Fabric OS 6.2.2f Release Notes (5697-1756, February 2012)

Table 14 Fabric OS 6.2.2c closed defects (continued)
SolutionClosed defect summary
/fabos/libexec/webdconfigure as root to set "HTTP
Enable" to yes. Or schedule a window, disable switch, and
configdownload a file with http.enable:1 [end] when
switch is at FOS 6.1.x to correct the configuration.
If the switch is already stuck in a reboot loop, login as root
via serial console, copy and paste the following command string
into console as one line before the next reboot:
sed 's/http.enabled:1/http.enabled:1/g'
</etc/fabos/fabos.0.conf> tmp;
cp tmp /etc/fabos/fabos.0.conf;cp tmp
/mnt/etc/fabos/fabos.0.conf;rm tmp
Fixed in Fabric OS 6.2.2c.After hot code load, switch in access gateway mode
panics and reboots, and usually a [PORT-1003] is
entered in raslog.
Fixed in Fabric OS 6.2.2c.VE tunnel bounce, VEx/Ex port bounce observed after
hareboot on 8 Gb switch configured for FCR under
heavy load condition. This impacts HP StorageWorks
400 Multiprotocol router, multiprotocol router blade,
or any 8 Gb switch configured with VEx/Ex/VE ports.
Fabric OS 6.2.2c now exposes these counters through SNMPAll 64 bit port status counters not available in SNMP,
even though they are available in the CLI using the
portStats64Show command.
Fixed in Fabric OS 6.2.2c.Running supportsaves -k multiple times on FOS
6.2.x causes raslogd to crash and restart. This can
lead to hafailover on directors and reboot on
switches.
With Fabric OS v6.2.2c, this specific occurrence of CDR-1003
is updated to log as a warning rather than critical. It can be
On B-series 4 Gb switches, multiple critical level
CDR-1003 raslog entries seen during
safely ignored unless it becomes persistent, or does not happen
during supportsave.
supportsave after non-disruptive upgrade from FOS
6.1.x to 6.2.x.
Fixed in Fabric OS 6.2.2c.
Workaround prior to update:
WebTools nameserver is not reflecting the alias and
zones created in DCFM. Alias and zone to which the
Use WebTools to create a zone/alias rather than DCFM.
device belongs is not displayed in the "member of
zone" and "member of alias" column.
Fabric OS 6.2.2d fixes
Table 15 (page 47) lists defects closed in the Fabric OS 6.2.2d firmware release.
Table 15 Fabric OS 6.2.2d closed defects
SolutionClosed defect summary
Fixed in Fabric OS 6.2.2d.During a reboot, the host might not come up when
connected to an HP StorageWorks 4/8 SAN Switch,
HP StorageWorks 4/16 SAN Switch, or Brocade 4
Gb SAN Switch for HP c-Class BladeSystem. The host
is unable to log in because the switch comes online
as a G_Port rather than an F_Port.
Fixed in Fabric OS 6.2.2d.Weblinker processes terminate and then restart when
the DCFM management application queries Top Talker
information from the switch.
Fixed in Fabric OS 6.2.2d.For all 8 Gb switches, the host is unable to discover
its targets after an HA failover or a code upgrade on
the router port. This is because the domain table
routing entry is accidentally cleared on an EX_Port.
Fabric OS 6.2.2d fixes 47