HP Fabric OS 6.2.2f Release Notes (5697-1756, February 2012)

Table 16 Fabric OS 6.2.2e closed defects (continued)
SolutionClosed defect summary
Switch, HP 8/8 (8)-ports Enabled SAN, HP 8/24 Base
16-ports Enabled SAN Switch Switch, HP 8/40 Base
24-ports Enabled SAN Switch, and the HP 8/40
Power Pack+ 24-ports SAN Switch.
Fixed in Fabric OS 6.2.2e.Access Gateway is not displayed by the DCFM client
when utilizing an EOS seed switch.
Fixed in Fabric OS 6.2.2e.When more than one RPC connection is established
simultaneously on a switch with busy management
applications, a race condition may cause multiple
connections to free a shared object and trigger rpcd
panic.
Fixed in Fabric OS 6.2.2e.After performing a LOGO following a firmware
download the switch route is not properly established.
The host cannot see the target because the PLOGI
Accept from the HBA is dropped by the switch.
Fixed in Fabric OS 6.2.2e.The LED for online trunked F-Ports goes from a steady
green to off after a code upgrade or
hareboot/hafailover.
Fixed in Fabric OS 6.2.2e.A switch panic occurs when a management
application polls for Access Gateway device
information or when agshow command is executed.
Fixed in Fabric OS 6.2.2e.WARNING raslog messages of "[CDR-1003]"
unnecessarily generate the call home function.
Fixed in Fabric OS 6.2.2e.SNMPmibwalk only shows MIB connUnitPortEntries
for ports that have SFPs installed.
Fabric OS 6.2.2f fixes
Table 17 (page 49) lists defects closed in the Fabric OS 6.2.2f firmware release.
Table 17 Fabric OS 6.2.2e closed defects
SolutionClosed defect summary
Fixed in Fabric OS 6.2.2f.A device may not be accessible after FCIP links have
bounced multiple times in a Fibre Channel Backbone
fabric because the Fibre Channel Router is not
properly translating all SID/DIDs. Frames with the
same SID/DID were sent to the device after a proxy
translation failed in a backbone to edge FCR
configuration.
Fixed in Fabric OS 6.2.2f.IDLE not being sent after a NOS causes an issue and
one side the ISL becomes a G_Port, while the peer
remains an E_Port.
Fixed in Fabric OS 6.2.2f.A host is unable to link up to an 8 Gb FC port when
the 8 Gb-capable port is configured at a fixed 4 or
8 Gb speed and the remote port is configured at auto
negotiation speed, and there is only one port
connected to the remote switch.
Fixed in Fabric OS 6.2.2f.An F_Port may become stuck in a disabled state and
report a raslog: [AG-1005] error after an Acesss
Gateway reboot.
Fixed in Fabric OS 6.2.2f.FAN frames are not being sent by the switch to loop
devices after LIP when fcAL.fanFrameDisable is set to
Fabric OS 6.2.2f fixes 49