A Specifications
Switch Specifications
Operating Conditions
The switch must be operated in a clean, dry environment with unrestricted airflow. Air flows in through
the cosmetic end and out through the business end (sometimes called the transceiver end or
“back-of-box”).
To avoid overheating, maintain a minimum clearance of two inches (50.8 millimeters) on each end of
the switch (the cosmetic end and the business end). Allow an adequate amount of space on the top
and sides of the switch for proper air ventilation. Do not place the switch on heat-generating surfaces.
Operating conditions are listed below.
Specification Value
Number of Ports 12
Operating Rate All ports operate independently at 1.0625 or 2.125 Gb/s
Port Media Type SFP optical or copper based
Enclosure 1U half-rack form-factor
Management Interface Fibre Channel, RS-232, or 10/100 Ethernet
EU Compliance EU directive 2002/95/EC
Configurability Management interface configurable
Power On Selftest (POST) Yes
Dimensions 8.5" x 1.73" x 14.50" (W x H x D)
AC Power Input 50 or 60 Hz / 100 – 250 VAC / 1.0 – 0.5 A
AC Power Connector IEC connector
Weight Approximately 7 lbs.
Requirement Value
Operating Temperature 0°C to 40°C normal operation (ambient air temperature)
Storage -40°C to 80°C non-condensing
Power 50 or 60 Hz / 100 – 250 VAC / 1.0 – 0.5 A