HP EVA4000/6000/8000 and EVA4100/6100/8100 Updating Product Software Guide (XCS 6.250) (5697-1716, February 2012)

have only two versions of controller software. You cannot have more than two versions in an
HP P6000 Continuous Access environment.
While the HP P6000 Continuous Access storage systems are running different controller
software versions, you cannot make any configuration changes to your storage systems (for
example, do not add or delete DR groups or members of DR groups).
You must perform the upgrades to the storage systems in the HP P6000 Continuous Access
relationship within 60 days (1,440 hours) so that all arrays are running the same controller
software versions the same. After upgrading the first storage system, wait at least three minutes
before upgrading the second storage system. Ensure that the previously described requirements
are met on the second storage system.
If you need to upgrade both XCS and VCS, complete the upgrade of one before upgrading
the other. For example, upgrade all arrays running VCS before upgrading arrays running
XCS.
Ensure that no DR group is logging, merging, or copying. For all DR groups, ensure that the
failsafe state is Unlocked and the Failsafe on unavailable member mode is Disabled.
Ensure the connection between the storage systems is not compromised or failed.
Click the Data Replication folder in the Navigation pane.1.
2. Check the Connection State in the Data Replication Folder Properties window.
All EVA storage systems must be running normally with fully functional controller pairs.
Upgrading disk drive firmware in an HP P6000 Continuous Access environment
When upgrading disk drive firmware in an HP P6000 Continuous Access environment, the following
requirements must be met:
Perform the disk drive firmware upgrade using the local management server (the server running
HP P6000 Command View that is local to the EVA being upgraded).
Do not perform HP P6000 Continuous Access copy/merge activities across sites, site failovers,
cloning, or grouping/ungrouping of disks during an upgrade.
Do not add or remove members from DR groups.
For all DR groups, ensure that the failsafe state is Unlocked and the Failsafe on unavailable
member mode is Disabled.
Suspend replication and disable the intersite link or modify zoning to isolate the source array
from the destination array.
Upgrade the disk drive firmware on the destination array.
Re-establish intersite link communication between the arrays and resume replication, allowing
the DR group merges to complete.
Perform site failover.
Suspend replication and disable the intersite link or modify zoning to isolate the source array
from the destination array.
Upgrade the disk drive firmware on the new destination array (before site failover, this was
the source array).
Re-establish intersite link communication between the arrays and resume replication, allowing
the DR group merges to complete.
Perform site failback.
Preparing an HP P6000 Continuous Access environment for upgrading 35