HP EVA4000/6000/8000 and EVA4100/6100/8100 Updating Product Software Guide (XCS 6.250) (5697-1716, February 2012)

3. If you have not already done so, download the disk drive firmware file from the following
website:
http://www.hp.com/support/evadiskfirmware
a. Store the file in a known local directory. If you are running HP Command View EVA 9.x
or later, continue with step 4.
NOTE: It is recommended that you use the default directory of C:\Program Files\
Hewlett-Packard\Sanworks\CodeLoad. If you use a different directory, you will
have to enter the complete path when identifying the location of the firmware files.
b. If you are running HP Command View EVA 8.x or earlier, unzip the bundled image file
and place the files in a directory where HP Command View EVA resides (HP recommends
that you use the default directory noted in Step 3a.)
Continue with step 4.
4. Open and log in to HP P6000 Command View.
5. In the navigation pane, select the array for which you want to update hard disk drive firmware.
The Initialized Storage Systems Properties window opens.
6. Select the System Options tab.
The System Options window opens.
7. Click Code load system.
The Code Load Selection window opens Figure 18 (page 51).
Figure 18 Code Load Selection window disk drives
Click Continue to proceed or Cancel to exit the procedure.
8. Choose Code Load Disk Drives Online and click Select to proceed or Cancel to exit.
The Code Load Disk Drives Online - Page 1 window opens.
Step 6. Upgrading disk drive firmware 51