HP EVA4000/6000/8000 and EVA4100/6100/8100 Updating Product Software Guide (XCS 6.250) (5697-1716, February 2012)

Cause
HP P6000 Command View may have lost communication with the controllers. Two possible scenarios
are:
The management server HBA may have timed out commands to the controllers. See “Unknown
storage system—cause 1” (page 64).
The controllers are running a version of XCS that HP P6000 Command View does not
recognize. See “Unknown storage system—cause 2” (page 64).
Resolution
Unknown storage system—cause 1
If the array has a heavy I/O load, the HBA in the management server may time out commands to
the controllers. If this occurs, the storage system appears in the Unknown state.
Corrective Action
This scenario should correct itself in less than one minute. Alternately, you can perform a Rediscover
operation to initiate new commands to the controller.
Unknown storage system—cause 2
HP P6000 Command View can only manage controllers that are running supported XCS versions.
Corrective Action
Ensure that you are running the HP P6000 Command View version that is compatible with XCS
6.250. See the "HP P6000 Command View interoperability support" table in the HP P6000
Enterprise Virtual Array Compatibility Reference to determine which version of HP P6000 Command
View you should be running. Then, upgrade HP P6000 Command View to a compatible version.
See “Reference documentation” (page 7) for the link to this document.
View is not set or view list is null
Symptom
The content pane shows an Operation Failed message with Details: View Is Not Set
or View List Is Null.
Cause
HP P6000 Command View cannot build the view of the storage system.
Resolution
Click OK. Wait one to five minutes, depending on the size of the storage system, and retry the
command generating this message. If you still cannot see the storage system, stop and restart HP
P6000 Command View.
Security credentials configuration
The following Windows-based security groups are required on the management server:
NOTE: Group names are case sensitive.
HP Storage Admins—This security group is required on the management server to enable
access to all features of HP P6000 Command View and must have at least one member (user
account). Members have view and manage capabilities.
HP Storage Users—Members have view capability only. This group is required only when a
group with extremely limited use of HP P6000 Command View is needed.
64 Troubleshooting