Troubleshooting
Introduction
The Power-On Self Test (POST) and the Windows Event Viewer are troubleshooting
utilities you can use for the FCA2355 Host Bus Adapter (HBA). This chapter explains
the use of these utilities in the event of an HBA problem.
POST Conditions and Results
Table 41 lists the HBA LED states with descriptions of each.The position of the
POST LED indicators is defined in Figure 1–1 and Table 1–1 of this guide.
If the LEDs indicate a failure during POST:
1. Make sure that the HBA is seated firmly in the PCI slot.
2. Verify that the fibre cable connection to the HBA is secure.
Table 4–1: HBA POST LED States
Amber LED (L1) Green LED (L2) Description
OFF OFF Wake-up failure (dead board)
ON OFF POST failure (dead board)
slow blink (1 Hz) OFF Wake-up failure (dead board)
fast blink (4 Hz) OFF Failure in POST (dead board)
flashing (irregular) OFF POST processing in progress
OFF ON Failure while functioning
ON ON Failure while functioning
slow blink (1 Hz) ON Normal - 1 Gb link rate
fast blink (4 Hz) ON Normal - 2 Gb link rate
OFF blink (1 Hz) Normal - link down or not yet started