HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Common Replacement Information and Procedures
52 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
Figure 16: PC and terminal to maintenance port connection
Caution: Connecting a maintenance port cable between the array controller
and the PC (or terminal) can cause radio and television interference and
cause the subsystem to operate outside Federal Communications Commission
(FCC) radiation guidelines and requirements.
To reduce or eliminate any radiated emissions issues, use excellently-shielded
serial cables, and ground them appropriately. Also, do
not
leave a
maintenance port cable connected to the array controller through the
maintenance port unless communication with the array controller is
necessary.
2. Turn on the PC or terminal.
3. Configure the terminal emulation software for 9600 baud, 8 data bits, 1 stop
bit, and no parity bit.
Note: See the note starting on page 50 and the tip on page 51 for details on the
baud rate.
1 Maintenance port
cable for a PC
connection
2 Maintenance port
Adapters (not shown),
9-pin D-sub to 25-pin
D-sub:
Male to female
(null modem)
Male to male
(null modem)
Male to male
(modem)